Home Current issue Instructions
About us Archives Login 
Editorial board Search articles Contact us
Home Print this page Email this page Users Online: 241
ORIGINAL ARTICLE
Year : 2013  |  Volume : 2  |  Issue : 2  |  Page : 144-150

Comparison of two different restoration materials and two different implant designs of implant-supported fixed cantilevered prostheses: A 3D finite element analysis


1 Department of Prosthodontics, Kirikkale University, Faculty of Dentistry, Kirikkale, Turkey
2 Department of Prosthodontics, Afyon Kocatepe University, Faculty of Dentistry, Afyonkarahisar, Turkey
3 Department of Prosthodontics, Bezmialem University, Faculty of Dentistry, Fatih, Istanbul, Turkey
4 Department of Prosthodontics, Ankara University, Faculty of Dentistry, Besevler, Ankara, Turkey

Correspondence Address:
Ahmet Kursad Culhaoglu
Doktor Mediha Eldem Sokak, No: 70/11 Kocatepe, Ankara
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2278-9626.112315

Rights and Permissions

Purpose: A key factor for the success or failure of a dental implant is the manner of stresses transferred to the surrounding bone. Parallel to this situation, cantilever extensions where it is not possible to place another implant, would cause greater stress and it should be avoided if possible. Manufacturers and clinicians try to develop new implant designs and superstructure materials to reduce the stresses around the implant and supporting bone tissue. This study analyzed the influence of superstructure materials and implant designs on stress distribution around dental implants supporting cantilever restoration under loading conditions. Materials and Methods: Three-dimensional finite element models of a 3-unit cantilever bridge were subjected to 150 N occlusal load to evaluate two different superstructure materials (conventional metal ceramic, fiber reinforced composite) and two different implant designs, cylinder type (Institut Straumann AG, Waldenburg, Switzerland) and cylinder type with micro threads around implant neck (Astra Tech AB, Mölndal, Sweden). To evaluate the distribution of stresses within the bone surrounding the implants, 3-dimensional finite element analysis was conducted using four mathematical models of unilateral 3-unit cantilever fixed partial dentures supported by two implants. Results: The stress distribution patterns and stress values were similar and stress concentrations were similar in both restoration materials. The highest stress concentrations were around the adjacent ITI implant, which supports the conventional metal porcelain restoration. Conclusions: Although, there was no significant difference in stress distribution between fiber reinforced composite (FRC) and conventional metal porcelain, stress values were lower in FRC restorations. The Astra-Tech micro-thread design reduced the stress that was distributed throughout the implant body, but it should be noted that the peak stress was still present on the implant neck.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3014    
    Printed92    
    Emailed0    
    PDF Downloaded601    
    Comments [Add]    
    Cited by others 3    

Recommend this journal